Globe Control Valves
Cage-guided, clamped-seat design for general to high-pressure service.
- Size
- 1"–24"
- Rating
- to Class 2500
- Trim
- Contoured · cage · anti-cavitation · low noise
- Shut-off
- Class IV · V · VI
Flow Control Commune designs, manufactures and tests standard, bespoke and severe-service control valves in Chennai, India. Supplied, sized and serviced in Malaysia by Flowmach Engineering.
Principal · Control valvesFlow Control Commune (FCC) is a control valve manufacturer based at SIPCOT Industrial Park, Chennai, India. Research and development, design, manufacturing, assembly and testing all take place under one roof, in an integrated 40,000 sq ft factory.
Founded in 2022 by a team with more than 30 years of control valve experience, FCC builds globe, cryogenic, butterfly and actuated control valves for oil and gas, LNG, air separation, refining, fertilizer, chemicals, power and water. Every design is verified with FEA and CFD and sized with FCC's own ISA- and IEC-compliant software. FCC valves serve customers in 14 countries.
Flowmach Engineering supports Malaysian operators and EPCs with FCC valve selection, sizing, supply and after-sales servicing from our workshops in Peninsular Malaysia and Borneo.
Cage-guided, clamped-seat globe valves, from general duty up to Class 2500.
A dedicated ASU and LNG range, including cold-box top-entry, Joule-Thomson and bellow seal valves, with Class VI shut-off down to −196 °C.
FEA, CFD, SolidWorks and Ansys design checks, with in-house sizing software compliant with ISA and IEC.
IEC 60534-4 seat leakage, API 598, ISO 15848 fugitive emission, API 607 fire safe and ISO 28921 cryogenic testing.
Oxygen-service valves are cleaned to EIGA 33/18, ASTM G93 and CGA G-4.1, assembled in an ISO Class 7 clean room and leak-tested with nitrogen, never air.
Flowmach engineers handle sizing, supply, installation support and reconditioning, close to your plant.
Add a series to your RFQ basket, or download its datasheet.

Cage-guided, clamped-seat design for general to high-pressure service.

Extended cryogenic bonnet for LNG and air separation service.

Double and triple offset designs with through-shaft and anti-blowout shaft.

Multi-spring diaphragm and piston actuators, field reversible, high thrust.
−196 °C
NDT by ASNT Level II / III personnel. Coatings inspected by a NACE Level II inspector.
Send your process data or instrument datasheet. Our engineers size the right FCC valve and reply with a quotation, normally within two working days.